Sulfur Compound Instruments
​​​​​​​​​​​​​​​​​​​​ Conta​​​ct us
Traini​ng
Sales Contacts
Request a Quote
Terms & Conditions
​​ ​ ​

​Model T102
​with NumaView™ Software

UV Fluorescence TRS Analyzer​

T102-TRS_web_2020_jpg.jpg

 Features

 

  • Ranges: 0-50 ppb to 0-10 ppm TRS and up to 20 ppm SO2, user selectable
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 8 analog inputs (optional)
  • Adaptive signal filtering optimizes response time
  • Temperature & pressure compensation
  • Auto zero system
  • Comprehensive internal data logging with programmable averaging periods
  • Ability to log virtually any operating parameter
  • Two-year warranty

 Downloads

  
  
  
083730101B - MANUAL, USER, NVS, T101-T102.pdfT101/T102 with NumaView™ Software Manual17127 KB
ESD Fundamentals - 04786.pdfFundamentals of Electro-Static Discharge (ESD)216 KB
NVS Remote Manual - 08492.pdfNumaView™ Software Remote User Guide867 KB
SAL000043D - T102.pdfT102 Specification828 KB
SAL000043E-CN T102.pdfT102规格 (Chinese Specification)5192 KB
SAL000076K - Environmental Instruments Overview.pdfEnvironmental Instruments Overview610 KB
T SERIES_6PG.BROCHURE_2018_web.pdfT Series with NumaView™ Software Brochure9567 KB

 Specifications

​​
Ranges​

TRS
Min: 0-50 ppb full scale
Max 0-10,000 ppb full scale
SO2
Up to 0-20,000 ppb full scale (selectable and dual range supported)
Measurement Units
ppb, ppm, μg/m3, mg/m3 (selectable)
Zero Noise < 0.2 ppb (RMS)
Span Noise < 0.5% of reading (RMS) above 50 ppb
Lower Detectable Limit < 0.4 ppb
Zero Drift < 0.5 ppb/24 hours
Span Drift < 0.5% of full scale/24 hours
Response Time
< 140 seconds to 95%
Linearity 1% of full scale
Precision 0.5% of reading above 50 ppb
Sample Flow Rate 650 cc/min ±10%
Power Requirements 100V-120V, 220V-240V, 50/60 Hz
Analog Output Ranges 10V, 5V, 1V, 0.1V (selectable)
Recorder Offset ±10%
Included I/O 1 x Ethernet: 10/100Base-T
2 x RS232 (300-115,200 baud)
2 x USB device ports
8 x opto-isolated digital outputs
6 x opto-isolated digital inputs
4 x analog outputs
Optional I/O 1 x USB com port
1 x RS485
4 x digital alarm outputs
Multidrop RS232
3 x 4 - 20mA current outputs
Operating Temperature Range 5 - 40°C (with US EPA Approval)
850°C (external converter)
Dimensions (HxWxD) Analyzer: 7” x 17” x 23.5” (178 x 432 x 597 mm)
Converter: 7” x 17” x 23.5" (178 x 432 x 597 mm)
Weight


Specifications are subject to change without notice.
All specifications are based on constant conditions
.​
Analyzer: 37 lbs (16.8 kg)
Converter: 20 lbs (9.1 kg)​​​



 Description

The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur at levels commonly required for ambient air monitoring.

The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%.  A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.

All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability.  All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.

The Model T102 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​