Sulfur Compound Instruments
​​​​​​​​​​​​​​​​​​​​​ Conta​​​ct us
Traini​ng
Sales Contacts
Request a Quote
Terms & Conditions
​​ ​
​​

 

​Model T100H
with NumaView™ Software

High Range UV Fluorescence SO2 Analyzer
T100H-SO2_web_2020_jpg.jpg

Features

 

  • Ranges: 0-10 ppm to 0-5,000 ppm, user selectable
  • Dual ranges
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 8 analog inputs (optional)
  • Adaptive signal filtering optimizes response time
  • Temperature & pressure compensation
  • Fast response (<30 seconds to 95%)
  • Comprehensive internal data logging with programmable averaging periods
  • Ability to log virtually any operating parameter
  • Two-year warranty

Downloads

  
  
  
22-002A REST API Tutorial For Numaview Instruments - SOX.pdfREST API Tutorial for NumaView Instruments584 KB
ESD Fundamentals - 04786.pdfFundamentals of Electro-Static Discharge (ESD)216 KB
NVS Remote Manual - 08492.pdfNumaView™ Software Remote User Guide867 KB
SAL000040D - T100H.pdfT100H Specification796 KB
SAL000040E-CN T100H.pdfT100H规格 (Chinese Specification)5241 KB
SAL000076K - Environmental Instruments Overview.pdfEnvironmental Instruments Overview610 KB
T SERIES_6PG.BROCHURE_2018_web.pdfT Series with NumaView™ Software Brochure9567 KB
T100 NVS Manual - 083730100.pdfT100/T100U/T100H with NumaView™ Software Manual14743 KB

Specifications

​​
Ranges Min: 0 - 10 ppm full scale
Max: 0 - 5,000 ppm full scale (selectable with dual range supported)
Measurement Units​ ppm, mg/m3 (selectable)
Zero Noise 0.1 ppm (RMS)
Span Noise < 1% of reading (RMS) above 10 ppm
Lower Detectable Limit < 0.2 ppm
Zero Drift < 1 ppm/24 hours
Span Drift < 0.5% of full scale/24 hours
Response Time < 40 seconds to 95%
Linearity 1% of full scale
Precision 0.5% of reading above 10 ppm
Sample Flow Rate 700 cc/min ±10%
Power Requirements 100V-120V, 220V-240V, 50/60 Hz
Analog Output Ranges 10V, 5V, 1V, 0.1V (selectable)
Recorder Offset ±10%
Included I/O 1 x Ethernet: 10/100Base-T
2 x RS232 (300-115,200 baud)
2 x USB device ports
8 x opto-isolated digital outputs
6 x opto-isolated digital inputs
4 x analog outputs
Optional I/O 1 x USB com port
1 x RS485
4 x digital alarm outputs
Multidrop RS232
3 x 4 - 20mA current outputs
Operating Temperature Range 5 - 40ºC
Dimensions (HxWxD) 7” x 17” x 23.5” (178 x 432 x 597 mm)
Weight



Specifications are subject to change without notice.
All specifications are based on constant conditions.​
Analyzer: 31 lbs (14 kg)
External pump: 15 lbs (7 kg) ​

Description

The Model T100H SO2 analyzer uses the proven UV fluorescence principle with the high measurement ranges and interferent rejection​​​ needed for extractive source monitoring.  The Model T100H provides a simple but precise solution for a broad range of CEM and stack testing applications.

The instrument design provides minimal quenching by O2 or CO2 and less than a 0.1% response to water in the sample. Additionally, special optical filtering reduces the effects of NO interference.​

All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability.  All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.

The Model T100H comes with NumaView ™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView ™ Software. ​